No.D6328 perforated raised floor

March 3rd, 2009

No.D6328 perforated raised floor is made up of perforated panel, damper, stringer, bolt system, shock absorbtion pad and pedestal. The loading ability of the perforated panel is weakened for common perforated raised floor as the top and bottom sheet is full of ventilation holes. But No. D6328 type floor is equipped with special reticulated steel grid at the cavity of the panel. So it is strong impact resistant. The type of products can just be installed on the space where ventilation is necessary instead of all room fit with this type of floor. The air flow rate can be adjusted as the damp is equipped with the panel. The rate can be 15%,23%,27%,37% and 52%.

No.D9860 OA access floor

March 2nd, 2009

No.D9860 OA access floor is specially designed for easy cable layout in computer room and net work room. The panel is mainly made up cold rolled steel sheets. And the steel sheets are well spot welded. The surface has been treated with antistatic coating and can be covered with HPL and PVC flooring. There are wire tank at the 4 sides of panel. Video line, volume line, data line and power line can be installed in the tank to offer a better look. Its support system is made up of grid stringer, corner lock, pedestal, shock absorbtion pad, screw and bolt. The pedestal is with manufactured with some special technology. No.D9860 OA access floor can be ultra-low. Its height can only be 8cm. So it can offer a bigger room space.

The pedestal system for OA raised floor

March 1st, 2009

The pedestal system for OA raised floor is made ups of pedestal, shockproof cushion and screw. The size of the top plate for the pedestal is 73*73*4mm. And the size of the bottom plate for the pedestal is 104*104*4mm. The diameter of the tube is 25cm. The height of the diameter is 30cm. The height is adjustable between 10cm and 30cm. The pedestal is plated with zinc to ensure corrosion proof. The top of the head is made of aluminum. The screw is used to fix each corner of the panel. So each panel can be freestanding with the help of corner lock system. The shockproof cushion is used to reduce noise when people work on it. With the help of the support system, OA raised floor is durable and widely used at net work room and office building.

No.9658 raised net floor

February 28th, 2009

No.9658 raised net floor is with special slot at the edge of panel. It is a brand new design! Its surface is treated with static painting. The 4 corners of the panel are locked. Each panel can be free standing. The dimensions of the panel can 600*600*30mm and 600*600*35mm. Its dimensions are of high precision. The tolerance of panel thickness is between 0.25mm. And The length and width tolerance is between -0.35mm and 0.05mm. The color of the panel can be white, gray and black. And the surface is strong corrosion resistant and strong impact resistant. It is waterproof and waterproof. The panel is easy to install, change and disassemble. There is screw under the panel and fit on the pedestal. The height of the panel can be lowered with adjusting the screw. No.9658 raised net floor is widely used at office building and computer room.

How to install bamboo flooring?

February 27th, 2009

Many people don’t know to install bamboo flooring. The points below may help your installation work:

1. Open the package in the installation area at least 4 days before the installation to make sure that bamboo flooring be used to the temperature and humidity.

2. Keep the installation space dry and flat. Paint moisture proof lacquer or fit underlay with PE film on the installation space.

3. Choose ceiling joist with hard and dry wooden wood plank. And the ceiling joist must not be wormy. Fit the ceiling joist to the subfloor and make it with multi cross appearance. The size of the cell should be around 20cm*20cm. Make the surface of ceiling joist flat. Keep at least 5 pcs of ceiling joist under plank.

4. Keep 0.6mm gap between each bamboo plank. Fix the bamboo plank on the ceiling joist with nail. The knock angle is should be around 45 degree.

5. The short side of the bamboo plank should head the door to have a better look.

6. Keep a 12mm wide gap between bamboo flooring and wall for the expansion purpose. Paint the cut end with varnish for the moisture proof purpose.

Bamboo flooring and ceramic tile

February 24th, 2009

Bamboo flooring(B) is usually installed neighboring to ceramic tile(C) whatever the place of the C. The transition space is usually covered by bamboo T-moulding or reducer. Sometimes copper reducer is also used. C is water resistant while B is not. There is often large amount of water on the surface of C which is installed in bathroom or kitchen. So it would be better that the surface of ceramic tile at these places is a bit lower that B and the surface is leaned to waterspout which is far from B. The color of bamboo flooring is usually natural bamboo, carbonized bamboo and strand woven design, which is a bit simple. So it is important to choose C with suitable color to match them. Usually beige color is a good selection. It seems red and black or other dark colors can’t match the color of B well.

Anti-Static Cement infilled raised access floor

February 23rd, 2009

The panel of anti-static cement infilled raised access floor is made of cold pulled steel sheet. The panel size can be 500*500*28mm or 600*600*32mm. The four edges of the panel are riveted. The cavity of the panel is full of foamed cement. The exterior of the panel of is antirust, phosphoreted and treated with epoxy powder coat. Its features are strong abrasion resistance, strong electric conduction, high bearing strength, smooth surface, strong corrosion proof and strong shock proof. The loading capacity can be 850LB, 1100LB and 1300LB. The product is widely used in all kinds of high grade office building, computer rooms, network room, laboratory, electrical control rooms, post and telecommunication centers and television transmitter control room.

Square-head pedestal for access floor

February 21st, 2009

Square-head pedestal for access floor is made up of head, axis, base and gasket. It is usually zinc coated. The thickness of head is around 4mm. The material of head can be aluminum alloy or steel. The thickness of base is around 3mm. The size of top is around 60*60mm. And the size of bottom is around 80*80mm. The gasket mainly consists of black rubber. It is put on the top of the head to reduce the noise when people step on the access floor. The pedestal is used to support the stringer system and corner locking system. It can be self-locked. The pedestal is vertically adjustable. And height range is from 120mm and 180mm. The axis load can reach 25kn. The minimum load capacity of the pedestal is 22,000N.

Case wiring raised floor

February 20th, 2009

Case wiring raised floor is made up of pedestal, stringers, locks, shock absord pad and foamed cement infilled panel with slots at the edge. PVC or HPL layer can be put on its top to offer a more beautiful look. Its main feature is its slots for wire. Various wires for volume, video and data can be installed in the slots in parallel. The wire put in the slots can reach any place of floor in the room. Wire pipes are not needed in this way and accordingly the cost is saved. Case wiring raised floor offers a beautiful look as the wires are hidden under floor. The pipes installed above the floor greatly affect the look of room. And the wires are easy to maintain. Open the slot cover and then the wire is easy check, repair or replace. Its height is adjustable as the height of pedestal can regulated. It’s suitable for office building and computer room.

How to remove the dirty lacquer on bamboo flooring?

February 14th, 2009

Someone had the wall of his house painted again. There is some lacquer falling on the bamboo flooring. And the lacquer hasn’t been removed for a long time. It has become solid and attached the floor firmly. He wonders how to remove the lacquer.

Below are some ways he can follow to do the clean work:
(1) Don’t use steel ball to rub the painted area. Also don’t use strong alkali or acid or cleanser to get ride to the lacquer as these ways will make the color of the touched area quite different from other floor place and affect its look.
 (2) Use moist mop to soften the lacquer. Scratch the lacquer with a knife. Avoid the edge of knife to scrape bamboo flooring as it is not strong abrasion resistant. Then use mop to get rid of the separate lacquer. For the left lacquer, wet it with acetone as acetone can dissolve the left lacquer. But the quantity of acetone can’t be too much is this type of floor is water proof. Get ride of the acetone as soon as the lacquer is got ride of.